Availability: | |
---|---|
Quantity: | |
| |
Nominal Voltage | 12V (6 cells) | |||
Nominal Capacity | 68.5AH (20hr, 1.80V/cell, 25°C/77°F) | |||
65AH (10hr, 1.80V/cell, 25°C/77°F) | ||||
55.3AH (5hr, 1.75V/cell, 25°C/77°F) | ||||
39AH (1hr, 1.60V/cell, 25°C/77°F) | ||||
Dimension | Length 350 ± 2mm | |||
Width 168 ± 2mm | ||||
Container Height 178 ± 2mm | ||||
Total Height(with Terminal) 178 ± 2mm | ||||
Approx Weight | Approx 21.0Kg | |||
Terminal | T3 or F5 | |||
Container Material | ABS | |||
Max. Discharge Current | 650A (5S) | |||
Internal Resistance | Approx 6.8mΩ |
SunStone Mainline (ML) series is 10 years designed life. For this long life purpose, the plates are made by developed alloy which is more effective for preventing corrosion. The main application of this series is UPS.
Sunstone Power has been ISO9001, ISO14001 approved and so on. In addition, many of our products have obtained CE, IEC61427, UL, VdS, RISTI ( by PT. TELKOM INDONESIA ) certificates.
Notice
1. Don’t near the hot source and don’t under the sunshine.
2. Don’t charge in the sealed container.
3. No short circuit. It should be the additional charge if you don’t use, and a single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid corrosion.
4. Don’t store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damaged, especially after one year using.
6. Don’t put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
8. Don’t clean the battery by using the organic solution. (e.g. petrol)
Nominal Voltage | 12V (6 cells) | |||
Nominal Capacity | 68.5AH (20hr, 1.80V/cell, 25°C/77°F) | |||
65AH (10hr, 1.80V/cell, 25°C/77°F) | ||||
55.3AH (5hr, 1.75V/cell, 25°C/77°F) | ||||
39AH (1hr, 1.60V/cell, 25°C/77°F) | ||||
Dimension | Length 350 ± 2mm | |||
Width 168 ± 2mm | ||||
Container Height 178 ± 2mm | ||||
Total Height(with Terminal) 178 ± 2mm | ||||
Approx Weight | Approx 21.0Kg | |||
Terminal | T3 or F5 | |||
Container Material | ABS | |||
Max. Discharge Current | 650A (5S) | |||
Internal Resistance | Approx 6.8mΩ |
SunStone Mainline (ML) series is 10 years designed life. For this long life purpose, the plates are made by developed alloy which is more effective for preventing corrosion. The main application of this series is UPS.
Sunstone Power has been ISO9001, ISO14001 approved and so on. In addition, many of our products have obtained CE, IEC61427, UL, VdS, RISTI ( by PT. TELKOM INDONESIA ) certificates.
Notice
1. Don’t near the hot source and don’t under the sunshine.
2. Don’t charge in the sealed container.
3. No short circuit. It should be the additional charge if you don’t use, and a single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid corrosion.
4. Don’t store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damaged, especially after one year using.
6. Don’t put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
8. Don’t clean the battery by using the organic solution. (e.g. petrol)